LNL-1200 Output Control Module
53.1.4
Power
For its power input, the series 2 Output Control Module accepts either a 12 to 24 VDC ± 10% power source.
The power source should be located as close to the Output Control Module as possible.
Wire the Power In input with 18 AWG (minimum) twisted pair cable.
Power Source
DC power source
Note:
Be sure to observe polarity.
53.2

Elevator Control

OnGuard hardware is capable of supporting elevator control for up to 128 floors. An elevator reader has an
input/output module that controls the access to floors via an elevator.
306 —
revision 7
Relay Output Wiring (Ports 2-5)
NC
C
NO
NC
C
NO
MOV
Requirements
Isolated, non-switching, regulated DC power
Power Source Wiring.
+
1 2 t o
2 4 V D C
-
W i r e w i t h
s t r a n d e d t w i s t e d p a i r .
FUSE
+
-
LOAD
FUSE
V I N
G N D
1 8
A W G
DC SOURCE
AC SOURCE
Current
500 mA