Wiring the V-Smart reader with the Dual Reader Interface Module
116.3.7
Establish Communication
For the V-Smart readers to function properly, the firmware must be version 7.61 or later. The firmware for
these units must be upgraded using VeriAdmin.
1.
Establish communication with the reader. Connect the cables according to the Veri-Series Setup Guide.
2.
Install the VeriAdmin software and start it.
3.
If you are configuring a new unit, the Network Setup screen will automatically be displayed. Click
[OK] to access the Network Configuration Manager. If this screen is not automatically displayed, from
the Configure menu, select Network Setup.
4.
Select the COM port to which the reader is connected.
5.
Click [Add unit]. The new reader will appear online. Be sure to verify its status on the screen.
116.3.8

LED Settings

1.
From the Configure menu, select LED Table Settings.
Power Ground (11)
Power In (8-12VDC 400 mA) (13)
Wiegand Ground (1)
Wiegand D0 Out (2)
Wiegand D1 Out (3)
TYPICAL SOFTWARE SETTINGS
1. Reader Type = Wiegand/Prox
2. Keypad = No Keypad
3. Network ID = 0
Hardware Installation Guide
Power
Supply
IDRC
Reader Port
GND
DATA/D0
CLK/D1
VO
revision 7 —
637