Elevator Control

OnGuard hardware is capable of supporting elevator control for up to 128 floors. An elevator reader has an
input/output module that controls the access to floors via an elevator.
The OnGuard software must be configured for elevator control. This can be done from System
Administration by selecting "LNL-1300 (IP Interface)" as the reader Type, and then selecting the Elevator
check box on the General tab in the Readers and Doors form. The reader's output, name, port, address, and
access panel can all be defined here as well.
Note:
In order for this check box to be available, the access panel to which this reader module is
connected must have Elevator support enabled on the Options tab.
With elevator control on the LNL-1300e, door strike, door contact, and REX (Request to EXit) are disabled.
Input/output panels (alarm panels) attached to the same controller as the LNL-1300e are used to interface
with the elevator controls. In addition, addresses assigned to input/output panels do not need to be
consecutive.
On the first panel, the inputs/outputs represent the first sixteen floors (for example: Input 1 = first floor,
Input 2 = second floor, etc.). The second panel represents the next sixteen floors (floor 17 through 32), etc.