For the Dual Reader Interface Module, make sure that jumper J2 is set to unregulated power mode.
This will allow the maximum amount of current for the readers.
Wiring the LPSP-6820 and the LNL-1320
From LNL-1320
Reader 1 or Reader 2 Pin
GND
DAT D0
CLK D1
BZR
LED
V0
Wiring the LPSP-6820 and the LNL-1320-U
From LNL-1320-U
Reader
Pin
Terminals
GND
J10
DAT D0
CLK D1
LED1
LED2
J13
BZR
V0
4.
Use a linear and regulated power supply, between 5 volts (50 mA peak) and 12 volts DC (80 mA peak).
5.
Align the reader with the electrical utility box. Attach the reader to the electrical box with screws.
6.
Put the reader's top cover in place and snap the housing closed.
7.
Power up the reader. The LED is steady amber. (The beeper does not sound.)
8.
Present any Lenel proximity credential (card, key tag, or wafer) briefly to the reader. The beeper sounds
a single short beep. The LED is steady red to indicate standby mode. This initializes the reader and
prepares it for reading cards authorized for this door or gate.
Note:
You must use Lenel credentials.
9.
If the LED color in standby is green (instead of red), it may be changed to red using a Color Changer
card, available from Lenel.
To LPSP-6820 Reader
Wire Color
Black
Green
White
Yellow
Brown
Red
To LPSP-6820 Reader
Wire Color
Black
Ground
Green
Data 0
White
Data 1
Brown
Green LED
Not connected
Not connected
Yellow
Buzzer
Red
5-12 VDC
Hardware Installation Guide
Typical Software Settings
Description
Ground
Data 0
Data 1
Beeper
LED
5-12 VDC
Description
Reader Type =
Wiegand/Prox
Keypad = No Keypad
LED Mode = 1-Wire
LED Control
Typical Software Settings
Reader Type =
Wiegand/Prox
Keypad = No Keypad
LED Mode = 1-Wire
LED Control