LNL-1200-U Output Control Module
61

Specifications

Note:
For UL installations, refer to section
The LNL-1200-U is for connection to low voltage, class 2 power-limited circuits only. These specifications
are subject to change without notice.
Primary power: 12 to 24 VDC + 10%
-
12 VDC @ 805 mA nominal
-
24 VDC @ 407 mA nominal
-
33 BTU/hour
Relay contacts: 16 Form-C contacts: Relay 1-16 (K1-K11, K16-K20), 5 A @ 30 VDC
Inputs:
-
One (1) unsupervised, dedicated external (cabinet) tamper
-
One (1) unsupervised, AC power fail
Upstream communication: RS-485 2-wire, 2400 to 38400 bps
-
Does not support encryption
Cable requirements:
-
Power: 1 stranded twisted pair, 18 AWG
-
RS-485: 24 AWG, 120 ohm impedance, stranded twisted pair(s) with shield, 4000 feet (1219 m)
maximum
-
Inputs:1 stranded twisted pair, 30 ohms maximum
-
Outputs: as required for the load
Mechanical:
-
Dimension: 5 x 8 x 1.25 in. (127 x 203 x 32 mm)
-
Weight: 12.2 oz. (346 g) nominal
Environmental:
-
Temperature: -10 to +70°C (14 to 158° F) operating, -40 to +85°C (-40 to 185°F) storage
-
Humidity: 10% at 93°C (199°F) non-condensing operating, 10 to 95% at 85°C (185°F) non-
condensing storage
Certifications:
-
FCC Part 15
-
ETL 294, s319
-
UL294, 1076
-
C-Tick N22193
-
CE marking
-
RoHS
-
Environmental class: Indoor dry
-
WEEE
332 —
revision 7
UL Listed Installations