The system is to be installed within a protected premise. In a subassembly, the operating temperature range
must be 0° to 49°C; the humidity range must be 0 to 85% RH.
This system must be installed in accordance with the National Electrical Code (NFPA 70), and the local
authority having jurisdiction. If you are located in Canada, please refer to the Canadian Electrical Code.
For UL Installations, the central supervisory station equipment must be UL Listed to:
Information Technology Equipment, UL/CSA 60950
For UL Installations, use UL Listed information technology equipment. The computer minimum platform
requirements are as follows.
Intel Pentium 4 dual core processor
3.4 GHz clock speed
2 GB RAM
6 GB of hard drive space for OnGuard
DVD-ROM drive
One (1) USB port
Operating systems:
-
Windows Server 2012 R2
-
Windows Server 2012
-
Windows 7
-
Windows 8/Windows 8.1
Microsoft SQL Server 2014 (32 and 64-bit), SQL 2014 Express, Microsoft SQL Server 2012 (32 and
64-bit), or SQL 2012 Express
Access control/proprietary burglary systems:
-
OnGuard 7.0 (7.0.000) using Hardware Installation Guide revision 4.0.###
-
OnGuard 7.1 (7.1.000) using Hardware Installation Guide revision 5.0.###
-
OnGuard 7.2 (7.2.000) using Hardware Installation Guide revision 6.0.###
-
OnGuard 7.3 (7.3.000) using Hardware Installation Guide revision 7.0.###
NEC ExpressCluster X R3 Fault Tolerant software
The following devices must be incorporated into the system:
Supply line transient protection complying with the Standard for Transient Voltage Surge Suppressors,
UL 1449, with a maximum marked rating of 330 V.
Signal line transient protection complying with the Standard for Protectors for Data Communications
and Fire Alarm Circuits, UL 497B, with a maximum marked rating of 50 V.
Signal line transient protection complying with the Standard for Protectors in Telecommunication
Networks, CAN/CSA-C22.2 No. 226-92.
Equipment must be installed in a temperature controlled environment, maintained between 13 - 35°C (55 -
95°F) by the HVAC system. 24 hours of standby must be provided for the HVAC system.
HVAC rated modules were not evaluated by UL for Lenel OnGuard UL1076 product Listing.