Lenel OnGuard Hardware Installation Manual page 214

Table of Contents

Advertisement

ISC Communications
41.2.3
Configuring the ETHLAN
Any additional changes specific to the hardware that the Lantronix box is connecting to should be made
now. These may include, but are not limited to, baud rate, parity, stop bit, byte size, and flow control.
1.
Make sure the device is powered, completely booted, and connected to the network. Start
HyperTerminal.
2.
You will be prompted for a session name. Enter a name of your choice.
3.
Connect to the device using the IP address, port address of 7000.
4.
A HyperTerminal session starts. Type:
access
and press <Enter>. The access command will not echo.
5.
You will be prompted for a user name. Enter any name. There should be a command prompt.
6.
Type:
set privileged
and press <Enter>.
7.
The password prompt will appear. The password is system.
8.
For baud rate, type:
change speed [SPEED]
and press <Enter> where [SPEED] = the baud rate (9600, 2400, etc.)
9.
For parity, type:
change parity [PARITY]
and press <Enter>, where [PARITY] = none, even, odd, mark, or space.
10. For stop bits, type:
change stopbits [BITS]
and press <Enter>, where [BITS] = 0, 1, or 2.
11. For byte size, type:
change charsize [SIZE]
and press <Enter>, where [SIZE] = 7 or 8.