112.2.2
Wiring the MIFARE/iCLASS HandKey for Verification
The MIFARE/iCLASS HandKey reader must be wired to a single or dual reader interface module (LNL-
1300 or 1320). It will NOT function when wired to the biometric gateway.
12 V DC or AC
+
-
Configure the MIFARE/iCLASS HandKey Reader for Verification
In order to function properly with the OnGuard software, the MIFARE HandKey reader must be running
firmware version HK2-11045A.247 or higher. The iCLASS HandKey reader must be running firmware
HK2-11142A.175 or higher.
To set the properties, you will be asked a series of Yes/No questions. Follow the prompts on the display.
Pressing the [*/No] button will bypass the setting and take you to the next menu option. Pressing the [#/Yes]
button will allow you to change the current setting.
1.
To enter the Setup Menu, press both the [Clear] and [Enter] keys at the same time. When prompted for
the password, enter the default, [2], followed by the [Enter] button.
2.
Set the language.
The default is English. If this is acceptable, press [*/No] to move onto the next option.
If you wish to change it, enter [#Yes] at the prompt to set the language. Once you do this, selecting [*/
No] will allow you to pass each current language setting. When your preferred language is displayed,
press the [#/Yes] button. The display will return to the start of the SET LANGUAGE command. Select
[*/No] to move onto the next menu.
Back of MIFARE HandKey
1
2
3
4
5
6
7
8
Hardware Installation Guide
9
10
11
12
13
14
Dual Reader
Interface Module
VO
LED
BZR
CLK/D1
DATA/D0
GND
597