Configuration; Setting Dip Switches - Lenel OnGuard Hardware Installation Manual

Table of Contents

Advertisement

LNL-2000 Intelligent System Controller
20

Configuration

The ISC board contains 8 DIP switches and 23 jumpers that must be configured appropriately for your
system.
20.1

Setting DIP Switches

The following chart describes the use of each DIP Switch
DIP SWITCH(ES)
1, 2, 3
4
5
6, 7
8
20.1.1
Processor Address
To configure the processor address, set DIP switches 1, 2, and 3 according to the following table.
Address
1:
0 (default)
off
1
ON
2
off
3
ON
4
off
5
ON
6
off
7
ON
104 —
revision 7
DIP Switches (default)
ON
1
2
3
USED TO CONFIGURE:
Processor address (0 - 7)
Port 6: Hardware Flow Control (ON, by default)
Port 1: Hardware Flow Control (ON, by default)
Communication baud rate (115200, 38400 - default, 19200, 9600 bps)
Communication password status ("required", "not required")
DIP SWITCH
2:
3:
off
off
off
off
ON
off
ON
off
off
ON
off
ON
ON
ON
ON
ON
ON
ON
ON
4
5
6
7
8