Lenel OnGuard Hardware Installation Manual page 235

Table of Contents

Advertisement

3.
Hold down the <X> key on your keyboard and plug the power back into the UDS device. This will
allow you to enter the setup mode on the ETHLAN.
4.
At this point, type <Enter>, and follow the onscreen instructions for programming.
5.
When prompted for a password, please use UDS and press <Enter>.
Step 2: Establish network communication
1.
Determine the IP address that will be programmed into the UDS.
2.
Enter the Server Configuration menu by typing 0 and hitting <Enter>.
3.
Follow the onscreen instructions and enter all your necessary network settings.
4.
Refer to the manufacturer manual when entering the subnet mask information. Note: for standard class
C subnet, enter an 8.
5.
Once you have finished entering all your custom network settings, type a 9 at the prompt. This will save
all your network configurations and reboot the UDS.
6.
You can close your current HyperTerminal session.