UL Listed Installations

For UL installations per U294, the following must be observed:
RS-485 is "Not Evaluated by UL" and therefore cannot be used in UL installations.
Each field-wiring terminal is suitable for single conductor (wire) only. For detailed mounting
instructions, refer to the Hardware Installation Guide (DOC-600).
For use with separately Listed compatible control units and accessories as indicated in the installation
instructions of the end-use application.
Environmental for UL installations:
-
Temperature: -10 to +49°C (14 to 120°F) operating
Humidity: 85+/-5% at 30+/-2°C (86°F)