Hitachi Compute Blade 500 Series User Manual page 111

Logical partitioning manager
Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

Fail-Over
Failure of shared NIC service might not be detected (depends on the timing
failure occurring when using MSCS/MSFC). Switching from Active server to
Standby server would not be executed if the failure is not detected.
Location of Failure
Guest OS
LPAR manager
Notes:
1
All applied NICs for the Guest OS become unusable if a failure occurs in the shared
.
NIC service. In this case, the Guest OS cannot access network at all, though the
other functions work normally. So the Guest OS not releases Quorum disk.
Therefore the Active State of server cannot be switched to the Standby server which
cannot obtain the Quorum disk.
Guest OS has to be shut-down from management PC by using remote console
function when a failure occurred in the shared NIC service.
Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide
Figure 3-2 LU Access Conflict
Table 3-5 Failure Detected Location
Hyper Visor
FC Sharing Service
NIC Sharing Service
High Reliability Functions
Switching Server
Switchable
Switchable
Switchable
Un-switchable case exists
1
3-11

Advertisement

Table of Contents
loading

Table of Contents