Hitachi Compute Blade 500 Series User Manual page 137

Logical partitioning manager
Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

Be sure to save the configuration after NTP setting is enabled.RTC
time of LPAR might not synchronize as correction time of NTP, if you
rebooted without saving the configuration.
When adjusting LPAR manager system time by the NTP server, make
sure to use the same time zone between the management module,
BMC, and LPAR manager. If not, each clocks show the different time
and you cannot know the correct time when a failure occurs.
The setting of the adjustment by the management module for both
BMC and LPAR manager is recommended.
– Move to the Date and Time screen.
– Press [F7]: Change System Time Zone on the Date and Time screen to
display a sub-screen. Set a time zone and press [Enter].
– Place the cursor on TimeSync on the Date and Time screen and press
[Enter] to display a sub-screen. Select "SVP" and press [Enter].
Figure 5-7 Sub-screen of the Data and Time screen
– Check that NTP is set to SYNC on the System Service State screen.
Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide
Figure 5-6 Data and Time screen
Figure 5-8 System Service State screen
Setup of LPAR manager
5-7