Hitachi Compute Blade 500 Series User Manual page 339

Logical partitioning manager
Hide thumbs Also See for Compute Blade 500 Series:
Table of Contents

Advertisement

Message Content
Explanation
What to do
Message Content
Explanation
What to do
Message Content
Explanation
What to do
Message Content
Explanation
What to do
Message Content
Explanation
What to do
Message Content
Explanation
Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide
Error: Network error occurred,retry using the other port.
(Port0->Port1,Cmd:[0xXXXX],detected code[0xXXXX],error
Because a network error occurred, the communication port will be
switched from Port0 (Mgmt0) to Port1 (Mgmt1), and then
communication will be retried.
Check there are not any problems in a setup of a network, a LAN
switch and a connection.
Error: Notification to BMC failed.(Step:[0xXXXX],SubStep:
[0xXXXX],status:[0xXXXX],code:[0xXXXX])
Failed a noticing of an operation status to management module.
Failed to access to BMC.
If this message appears as often as LPAR manager boot, contact
the reseller from which you purchased this equipment or consult
maintenance personnel.
LP-Loader could not find any network controller.
Communication NIC detection failed.
Contact the reseller from which you purchased this equipment or
consult maintenance personnel.
LP-Loader could not find HyperArea.
LP-Loader could not allocate the data area for LPAR manager
(case2).
Confirm that "MM Config Base" is "2GB" in the EFI-setup menu.
When it is not "2 GB", set it to "2GB", turn off a power supply
once, and reboot the LPAR manager.
For details, see the Hitachi Compute Blade 500 series EFI User's
Guide.
LP-Loader could not find VfcSeed.dat in management
VfcSeed.dat file, having the Vfc seed information, cannot be
found in management module when the N+M was performed.
The switching N+M t might be failed, check the BSM error. When
there is no error, Contact the reseller from which you purchased
this equipment or consult maintenance personnel.
LP-Loader could not update OEM FRU
Updating the Vfc seed information to FRU failed when the N+M
was performed.
Messages