[Alert]
Using NTP
– Check LPAR manager system time on the Date and Time screen. If the
LPAR manager system time is not synchronized, adjust the LPAR manager
system time by restoring the NTP server network state.
– Adjust deactivated LPAR time using Adjust LPAR Time for LP System
Time, Specified Zone, and UTC, on the Date and Time screen. For
activated LPARs, adjust the time by using the guest OS or NTP time
synchronization for the guest OS.
– Enable the Save Time Config on the Options screen.
– On the Menu screen, press [F9]: Save Configuration to save the
configuration.
Not using NTP
– Check LPAR manager system time on the Date and Time screen. If it is
not the expected one, set the LPAR manager system time zone using F7:
Change System Time Zone.
– Check LPAR manager system time on the Date and Time screen. If the
LPAR manager system time is not synchronized, adjust the LPAR manager
system time by F6: Change System Date and Time.
– Adjust deactivated LPAR time using Adjust LP Time for LP System Time,
Specified Zone, and UTC, on the Date and Time screen. For activated
LPARs, adjust the time by using the guest OS or NTP time synchronization
for the guest OS.
– Enable the Save Time Config on the Options screen.
– Save the configuration on the Menu screen using F9: Save
Configuration.