No.
Item
Fail: Communication with the
management module is disabled.
Link: displays the link state.
Yes: "Linked up"
No: "Link down"
Port#: displays the port number of the
management path.
Displays the management path status.
Port#: displays the NIC and port number of
the management path(Mgmt0/Mgmt1).
State: displays the status of the
management path.
Active: The path is in the active state,
and is used for communication with the
management module.
Standby: The path is in the standby
state, and can be used for external
communication.
Error: The path is in a network failure
state.
Link down: The path is in a link-down
state.
Unknown: LPAR manager is unable to
communicate externally.
-----: No port is specified for the path.
This item is displayed if firmware
combination supports changing
management path settings.
For the firmware combination details, see
"Firmware
(11)
TYPE
Shows the type of the PCI device in the
shared scheduling mode on the [PCI Device
Assignment] screen.
N: Network interface Card (NIC)
Add "v" to the end of line when using VF
NIC.
F: Fibre Channel
(12)
NIC#
Displays the shared NIC number (1 ~ 6)
when the device type is No shown in (7).
Displays "-" when the device type is F in
(7).
(13)
PORT#
Displays the port number (0 ~ 3).
(14)
SLOT#
Displays the slot number.
Operation by LPAR manager Screen
Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide
Description
combinations".
Supported
Default
LPAR
Value
manager
Version
-
02-1X~
-
01-0X~
-
01-0X~
-
01-0X~
-
01-0X~
7-73