UPS Function
Scheduled power re-supply
Legend:
Y: Supported
N: Not supported
Notes:
1
Power management software shuts down the Guest OS by the signal which comes
.
from UPS. (LPAR status becomes "Deactivate")
2
The LPAR manager does not shut-down itself by the signal from UPS. The LPAR
.
manager shuts down itself only when all the LPARs status became "Deactivate".
("Auto Shutdown" function has to be set to "Enable")
3
LPARs can be automatically activated when power supply from UPS has recovered.
.
("Auto Activate" function has to be set to "Enable")
Note:
•
When UPS is used in the LPAR manager environment, it takes about 30
seconds longer for the server blade to stop working after a power failure
than in the Basic environment. More time may be required depending on
the number of activated LPARs.
Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide
Power control supporting matrix on LP mode
LPAR (Guest OS)
3
N
Figure 3-4 Outline of UPS Function
High Reliability Functions
Physical Server (LPAR
manager)
Y
3-13