24.4 UM Configuration—[5-4] System Parameters—Parameters
Outside Transfer Sequence—EFA Transfer Sequence (Up to 16 digits / [0-9 * #
D F R T , ; N A])
Specifies the sequence the system uses to transfer calls to trunks using EFA (External Feature Access). This
setting should match the settings of the PBX.
Value Range
Max. 16 digits consisting of 0–9,
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause for 1 s (default)
; : Dial Pause for 3 s (default)
N: Telephone Number Dialling
A: Feature Access Code
0–9,
, #: Dial Code
Outside Transfer Sequence—EFA Transfer Reconnect Sequence on Busy (Up
to 16 digits / [0-9 * # D F R T , ; N A])
Specifies the sequence the system uses to reconnect the line when the party transferred with EFA (External
Feature Access) is busy. This setting should match the settings of the PBX.
Value Range
Max. 16 digits consisting of 0–9,
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause for 1 s (default)
; : Dial Pause for 3 s (default)
N: Telephone Number Dialling
A: Feature Access Code
0–9,
, #: Dial Code
Outside Transfer Sequence—EFA Transfer Reconnect Sequence on No Answer
(Up to 16 digits / [0-9 * # D F R T , ; N A])
Specifies the sequence the system uses to reconnect the line when the party transferred with EFA (External
Feature Access) does not answer. This setting should match the settings of the PBX.
Value Range
Max. 16 digits consisting of 0–9,
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
T: Dial Tone Detection
, : Dial Pause for 1 s (default)
; : Dial Pause for 3 s (default)
N: Telephone Number Dialling
A: Feature Access Code
0–9,
, #: Dial Code
840
PC Programming Manual
, # and special codes
, # and special codes
, # and special codes