9.10 PBX Configuration—[1-1] Configuration—Slot—Port Property—V-SIPGW
Register
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Connection
Indicates the port status. To change the status of the port, click the desired cell in the column, and then select
INS or OUS for the port.
This option is only available in On-line mode.
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Register Ability
Specifies whether to send the REGISTER message to the SIP server.
Value Range
Disable, Enable
Register Sending Interval
Specifies the maximum length of interval time after which the PBX sends the REGISTER message.
Value Range
10–86400 s
Un-Register Ability when port INS
Specifies whether to unregister the previous registration and send the REGISTER message to the SIP server
when the port status is set back to INS.
Value Range
Disable, Enable
Registrar Server Name
Specifies the domain name of the SIP server.
Value Range
Max. 100 characters
Registrar Server IP Address
Specifies the IP address of the SIP server. This setting is compulsory when a register IP address is provided.
Value Range
1.0.0.0–223.255.255.255