9.10 PBX Configuration—[1-1] Configuration—Slot—Port Property—V-SIPGW
1.
Ensure that the Trunk Adaptor is connected to the network and a power supply, and that all ports to be set
are OUS.
2.
Click Trunk Adaptor. The Trunk Adaptor List screen is displayed.
3.
Enter a name (20 characters or less) for the Trunk Adaptor in Trunk Adaptor Name.
4.
Enter the Trunk Adaptor's IP address in Trunk Adaptor IP Address.
5.
To confirm that the setting is correct, click CONNECT. If the setting is correct, the Trunk Adaptor's Web
Maintenance Console will open in a new browser window.
For details about the Trunk Adaptor's Web Maintenance Console, refer to the documentation of the Trunk
Adaptor.
6.
Click Next. The Set Trunk Adaptor window will open.
7.
In Virtual SIP Gateway - Port Property - No. Range, specify From and To to select a range of SIP
connections to be used with the Trunk Adaptor. These numbers correspond to the No. column of the main
Port Property screen.
8.
In Name : IP Address, select a name and IP address previously entered on the Trunk Adaptor List
screen.
9.
In SIP Server Port Number, enter the SIP server's port number.
10.
In SIP Account / User Name, enter a 3- to 5-digit number in From.
11.
Click Finish, and the following settings are implemented:
Provider Name and
Trunk Adaptor.
The
User Name and
SIP Account / User Name, increased by 1 for each connection (i.e. if "401" was specified, User
Name and
"402", etc.).
12.
In the Calling Party tab of the V-SIPGW—Port Property screen, set
PBX-CLIP for each port that was set to be used with the Trunk Adaptor.
Main
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Connection
Indicates the port status. To change the status of the port, click the desired cell in the column, and then select
INS or OUS for the port.
This option is only available in On-line mode.
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Connection Attribute
Specifies whether to connect a port to a Trunk Adaptor or use it as a SIP gateway.
Value Range
SIP Provider, Trunk Adaptor
246
PC Programming Manual
SIP Server IP Address in the Main tab will be set to match the selected
Authentication ID in the Account tab will be set to the value specified in
Authentication ID for No. 1 will be set to "401", and then for No. 2 they will be set to
From Header—User Part to