Phone Location
Specifies the type of extension connected to the port.
Value Range
Local: The extension is located on the same network as the PBX (standard configuration).
Remote (SBC): The extension is accessing the PBX remotely (Simple Remote Connection).
Remote (MRG): The extension is accessing the PBX remotely (use Media Relay Gateway).
Feature Guide References
5.2.2.3 Simple Remote Connection
Web-MC Ability
Specifies whether the Web programming is allowed on the KX-UT series SIP phone connected to the port by
enabling the Web port setting on the phone's menu. For details about Web programming for KX-UT series SIP
phones, refer to the documentation of the phone.
Value Range
Enable, Disable
Feature Guide References
5.2.2.3 Simple Remote Connection
Protocol for Remote SIP-MLT
Specifies the protocol to use for remote SIP phone data communication. HTTPS is strongly recommended for
remote SIP-MLT connections.
Value Range
HTTPS, HTTP
Note
A total of 20 HTTPS connections can be set per PBX site. If "HTTPS" is selected but the total number of
HTTPS connections available at the site will be exceeded by changing this setting, a warning message will
be displayed and the setting change will be cancelled.
Feature Guide References
5.2.2.3 Simple Remote Connection
9.20 PBX Configuration—[1-1] Configuration—Slot—Port Property—V-UTEXT