Panasonic kx-ns500 Pc Programming Manual page 253

Hide thumbs Also See for kx-ns500:
Table of Contents

Advertisement

Session Incoming Refresher Request
Specifies the type of method used for establishing the session interval.
Value Range
UAC, UAS
SIP 200 Response Timer (*100 ms)
Specifies the amount of time to wait for a SIP 200 (OK) response when establishing a connection between two
parties. (Specifying "0" will disable the timer.)
Value Range
0–18000 ´ 100 ms
SIP 18x Response Timer (s)
Specifies the amount of time to wait for a 18x response when establishing a connection between two parties.
Value Range
0–255 s
Proxy-Require Option
Specifies option tags in a Proxy-Require header field so that the SIP server is notified that the client is behind
a router with NAT enabled and firewall.
Value Range
Max. 100 characters
Failover Timer(INVITE)
Specifies the amount of time to wait for a response for an INVITE request.
Value Range
0–30 s
Failover Timer(REGISTER)
Specifies the amount of time to wait for a response for a REGISTER request.
Note
If 0 is specified, failover operation follows the T1/T2 timer.
While monitoring failover with OPTIONS, the applicable timer setting is applied to OPTIONS as well.
This setting cannot be changed while the V-SIPGW card is set to INS.
This setting cannot be changed when an additional channel is active.
Value Range
0–30 s
9.10 PBX Configuration—[1-1] Configuration—Slot—Port Property—V-SIPGW
PC Programming Manual
253

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents