Panasonic kx-ns500 Pc Programming Manual page 254

Hide thumbs Also See for kx-ns500:
Table of Contents

Advertisement

9.10 PBX Configuration—[1-1] Configuration—Slot—Port Property—V-SIPGW
Calling Party
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Connection
Indicates the port status. To change the status of the port, click the desired cell in the column, and then select
INS or OUS for the port.
This option is only available in On-line mode.
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Header Type
Specifies the header of the SIP message in which the caller information is stored.
Value Range
From Header, P-Preferred-Identity Header
From Header—User Part
Specifies the value to be stored in the username part of the SIP-URI of the From header.
Value Range
User Name, Authentication ID, PBX-CLIP
From Header—SIP-URI
Specifies the complete SIP-URI address of the From header. The configuration in From Header—User Part
will be invalid if this parameter is set.
Value Range
Max. 100 characters
P-Preferred-Identity Header—User Part
Specifies the value to be stored in the username part of the SIP-URI of the P-Preferred-Identity header.
Value Range
User Name, Authentication ID, PBX-CLIP
P-Preferred-Identity Header—SIP-URI
Specifies the complete SIP-URI address of the P-Preferred-Identity header. The configuration in
P-Preferred-Identity Header—User Part will be invalid if this parameter is set.
Value Range
Max. 100 characters