9.29 PBX Configuration—[1-1] Configuration—Slot—Card Property—E1 type Line Signal Setting
Value Range
No Detection: Meter pulses are not sent or received.
Outgoing call only: Sends a call charge meter pulse for outgoing trunk calls.
Both calls: Sends and receives call charge meter pulses.
Feature Guide References
2.29.1 E1 Line Service
Meter Pulse Detection—Bit Position
Specifies the bit position of a call charge meter pulse.
Value Range
A-bit, B-bit, C-bit, D-bit
Feature Guide References
2.29.1 E1 Line Service
Meter Pulse Detection—Length
Specifies the length that a call charge meter pulse must be for the PBX to recognise it as a call charge meter
pulse.
Value Range
8 ´ n (n=1–80) ms
Feature Guide References
2.29.1 E1 Line Service
DSP Gain Adjustment—DTMF Transmit
Specifies the output power of the DTMF signal sent from the DSP (Digital Signal Processor).
Value Range
-12 dB–3 dB
DSP Gain Adjustment—DTMF Receive
Specifies the strength range within which a DTMF signal must be for the DSP to recognise it as a DTMF signal.
Value Range
-42 - 0 dB – -11- 0 dB
DSP Gain Adjustment—MFC-R2 Transmit
Specifies the output power of MFC-R2 signals sent from the DSP.
362
PC Programming Manual