9.29 PBX Configuration—[1-1] Configuration—Slot—Card Property—E1 type Line Signal Setting
Value Range
-31 dB–0 dB
DSP Gain Adjustment—MFC-R2 Receive
Specifies the strength range within which an MFC-R2 signal must be for the DSP to recognise it as an MFC-R2
signal.
Value Range
-38 - 0 dB – -23 - 0 dB
Frame Error Detection—Error Detection
Specifies whether the PBX detects frame synchronisation errors.
Value Range
No, Yes
Frame Error Detection—Error Rate
Specifies the number of frame errors per second which the PBX needs to recognise a remote alarm. To enable
this setting, Frame Error Detection—Error Detection on this screen should be set to Yes.
Value Range
No limit, 16 x n (n=1–7) errors/s