Status Receive
Selects what happens to a call when the Status Message from the network does not match the actual status
of the call.
Value Range
Ignore: Ignore the Status Message from the network.
Disconnect: Disconnect the call.
CRC4 Mode
Enables the use of CRC4 for error checking. CRC (Cyclic Redundancy Check) is an error checking control
technique that uses a specific binary prime divisor that results in a unique remainder. It is usually a 16- to
32-bit character. (Assignable only when using the PRI30 card.)
Value Range
Disable, Enable
Line Coding
Selects the line coding type of the PRI PCM (Pulse Code Modulation) for the port. This setting is only available
when using the PRI23 card.
Value Range
B8ZS, AMI
Frame Sequence
Selects the type of frame sequence for the port. This setting is only available when using the PRI23 card.
Value Range
Extended Multi frame (ESF), 4-Frame Multi frame (F4), 12-Frame Multi frame (F12)
CO Setting
CO Setting parameters are not applicable to ports assigned as Extension in
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Port Type
Selects the port type.
Note
Each ISDN connection in a QSIG network must have a master port on one PBX and a slave port on
another PBX.
ISDN extensions can belong to an incoming call distribution group or idle extension hunting group. In
this case, an MSN can be assigned.
Value Range
CO: For connecting to public network
Extension: For connecting to extension
QSIG-Slave: For connecting to private network (slave port)
9.27 PBX Configuration—[1-1] Configuration—Slot—Port Property - PRI Port
Port Type.
PC Programming Manual