Value Range
Disable, Enable
PC Programming Manual References
17.3 PBX Configuration—[9-3] Private Network—Network Operator (VoIP)—
BLF data to Network Operator
Feature Guide References
4.3.5.1 Network Direct Station Selection (NDSS)
Network Data Transmission for Centralised Operator Feature—Data
Transmission Counter
Specifies the maximum number of "hops", or transmissions between two PBXs, before a packet of BLF data
is discarded.
Value Range
1–63
Feature Guide References
4.3.5.1 Network Direct Station Selection (NDSS)
Network Data Transmission for Centralised Operator Feature—Data
Broadcasting Interval Timer
Specifies the frequency of BLF data transmission. The PBX will send data over the network periodically
according to the interval specified here.
Value Range
100 ´ n (n=0–30) ms
Feature Guide References
4.3.5.1 Network Direct Station Selection (NDSS)
Network MSW Data Transmission for Centralised VM Feature—Data
Re-transmission : Repeat Counter
Specifies the number of times re-transmission of network message waiting notifications is repeated before
being cancelled.
Value Range
0–10
17.2 PBX Configuration—[9-2] Private Network—Network Data Transmission
IP-GW Card Slot No. to notify
PC Programming Manual
703