7.4.4 Utility—Monitor/Trace—CS Status Monitor—Air Sync Group
7.4.4 Utility—Monitor/Trace—CS Status Monitor—Air Sync Group
This utility monitors the status of CSs being synchronised with air synchronisation. CSs receive data from other
CSs that they are currently synchronised with. Current Sync CS information is displayed for IP-CSs that are
in INS status.
This option is only available at Installer level in On-line mode.
The displayed items for the Current Sync CS of each CS are as follows:
Item
CS Type
Shelf
Slot
Port
CS / Repeater
CS Name
CS ID
Monitored Value
Monitored Level
Error Rate (%)
To monitor the status of CSs
1.
From the Air Synchronisation Group Number drop-down list, select the desired Air Synchronisation
Group number.
2.
From the Interval Timer drop-down list, select the number of seconds between each automatic screen
refresh.
3.
Click Start to monitor the status of air synchronisation.
Monitoring will be performed and the screen will refresh according to the specified interval.
4.
Click Stop to end monitoring.
5.
To refresh the screen manually at any time, click Refresh.
6.
To collect the monitored data, click Start Capture.
7.
Click Stop Capture to finish and save the monitored data.
A dialogue box will be displayed.
8.
Navigate to the folder in which you want to save the file.
9.
Enter a file name.
10.
Click Save.
The dialogue box will close.
122
PC Programming Manual
Description
Type of CS that each CS is currently synchronised with.
The shelf number (or Virtual for IP-CSs) of the CS that each CS is currently
synchronised with.
Slot number of the CS that each CS is currently synchronised with.
Port number of the CS that each CS is currently synchronised with.
Indicates whether the CS that each CS is currently synchronised with is a
CS or Repeater.
Name of the CS that each CS is currently synchronised with.
12-digit ID number of the CS that each CS is currently synchronised with.
Monitored value (dBm) of the CS that each CS is currently synchronised
with.
Monitored level (signal strength level) of the CS that each CS is currently
synchronised with.
Error Rate of the CS for each CS that it is currently synchronised with.