Quantum scalar i500 User Manual page 564

Hide thumbs Also See for scalar i500:
Table of Contents

Advertisement

No.
Flag
55
Loading or
threading
failure
56
Unrecoverable
unload failure
57
Automation
interface failure
58
Microcode
failure
59
WORM
medium —
integrity check
failed
Scalar i500 User's Guide
Recommended Application Client
Severity
Message
C
The operation has failed because the
media cannot be loaded and threaded:
1. Remove the cartridge, inspect it as
specified in the product manual, and
retry the operation.
2. If the problem persists, call the tape
drive supplier help line.
C
The operation has failed because the
medium cannot be unloaded:
1. Do not attempt to extract the tape
cartridge.
2. Call the tape driver supplier help line.
C
The tape drive has a problem with the
automation interface:
1. Check the power to the automation
system.
2. Check the cables and cable
connections.
3. Call the supplier help line if problem
persists.
W
The tape drive has reset itself due to a
detected microcode fault. If problem
persists, call the supplier help line.
W
The tape drive has detected an
inconsistency during the WORM
medium integrity checks. Someone may
have tampered with the cartridge.
Probable Cause
The drive is unable to
load the media and
thread the tape.
The drive is unable to
unload the medium.
The drive has
identified an
interface fault.
Microcode bug.
Someone has
tampered with the
WORM medium.
545

Hide quick links:

Advertisement

Table of Contents