Preparing to Install an
Additional Expansion
Module
Scalar i500 User's Guide
Warning:
Warning:
Prepare to install an additional expansion module as follows:
12
Warning:
Caution:
Chapter 12 Installing, Removing, and Replacing
Adding Expansion Modules to an Existing Library
All libraries taller than 14U must be installed in a rack
having a main protective earthing (grounding) terminal,
and power must be supplied via an industrial plug and
socket-outlet and/or an appliance coupler complying with
IEC 60309 (or an equivalent national standard) and having
a protective earth (ground) conductor with a cross
sectional area of at least 1.5 mm
To ensure proper airflow and access space, Allow 60 cm
(24 inches) in the front and back of the library.
Without tape drives, tape cartridges, or power supplies, a
5U control module weighs approximately 60 lbs (27.2 kg).
A 9U expansion module, without tape drives, tape
cartridges, or power supplies, exceeds 65 lbs (29.5 kg).
To avoid serious injury, at least two people are required to
safely lift the modules.
Without tape drives, tape cartridges, or power supplies, a
5U control module weighs approximately 60 lbs (27.2 kg).
A 9U expansion module, without tape drives, tape
cartridges, or power supplies, exceeds 65 lbs (29.5 kg).
To avoid serious injury, at least two people are required to
safely lift the modules.
If the library contains a partition that spans modules, and
you plan to install the new expansion module between
those modules, you must delete the partition before
adding the new module, and re-create the partition after
installing the module.
2
(14 AWG).