Running Manual Edlm Tests - Quantum scalar i500 User Manual

Hide thumbs Also See for scalar i500:
Table of Contents

Advertisement

Running Manual EDLM
Tests
Scalar i500 User's Guide
4 To change the mode from Active to Paused or from Paused to Active,
click the button in the New column, and then click Apply.
The operation completes and, if successful, a Success message
appears.
5 Click Close to close the Success message.
You may wish to evaluate media outside of the automatic EDLM
8
scanning policies. To do this, you can run a manual EDLM scan. Manual
scans are given highest priority and go to the top of the scanning queue.
As soon as an EDLM scanning drive has finished its current scan, it will
accept the tape scheduled for a manual scan. Once all manual scans are
finished, the scan queue continues as normal.
Manual EDLM scans can be run on any tape in the library, as long the
following conditions are met:
• An EDLM license must be installed on the library.
• The EDLM library managed partition must be configured on the
library (see
page 218).
• The cartridge you want to scan must be readable by a tape drive in
the EDLM library managed partition per standard LTO-gen-based
backwards-compatibility limitations.
• The cartridge you want to scan must be labeled properly. Unlabeled
media cannot be selected for manual scans.
• The cartridge can be located in any partition, including the EDLM
library managed partition. However, the cartridge must not be
located in an EDLM drive.
• If a tape is currently being scanned, you cannot select it for manual
scanning.
To run a manual EDLM test, do the following:
1 Log on as an administrator.
2 Select Tools > EDLM > Test Selection.
The Tools - EDLM Test Selection screen appears.
Chapter 8 Extended Data Lifecycle Management
Step 4: Creating the EDLM Library Managed Partition
Incomplete EDLM Scans
on
228

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents