Scalar i500 User's Guide

The process for importing cartridges includes the following steps:
1 Go to the front of the library and insert cartridges into the I/E station.
2 Close the I/E station door.
The
screen appears on the operator panel if the
Assign I/E
Cartridge Assignment
screen (
Settings
Tools > System Settings
If the
screen appears, do the following:
Assign I/E
a Assign the cartridges to the appropriate partition by selecting a
partition listed on the
The partition button turns red after it has been selected.
If you select the wrong partition, open the I/E station
Caution:
door. Move the cartridge to a different I/E station slot
and close the I/E station door. The library will rescan
the I/E station, and the
again.
b
Select
.
Apply
If the selected partition is online, it will be taken offline before the
import operation is performed, and brought back online after the
operation is complete. If the library contains multiple partitions,
the import operation will not affect operations in other partitions.
Note:
If the operation does not complete successfully, the
partition remains offline until you turn it back online
manually or restart the library (see
Online or Offline
3 Use the
Import Media
client to import the cartridges into the partition. Follow the on-screen
prompts, or see the library's online Help for step-by-step procedures.
To access the online Help system, click the
of the Web client or operator panel user interface.
You need to provide the following information in the
screens to import media:
Chapter 9 Running Your Library
setting is enabled on the operator panel
).
screen.
Assign I/E
Assign I/E
on page 76).
screens on either the operator panel or the Web
Performing Media Operations
Manual
System
screen will appear
Taking a Partition
icon at the top right
Help
Import Media
249