b
From the back of the library, find the rear Y-rail release
mechanism, which is located in the interior of the right side of the
module. Squeeze the handle of the Y-rail release mechanism, lift
it out of its locked position, and slide it downward as far as it will
go.
10 Unpark the robot assembly.
a Gently raise the robot assembly so that it no longer rests on the
parking tab.
Support the robot assembly by holding onto the broad
Caution:
metal X-axis plate. Lifting the robot by the thin metal
rod will bend the rod. Lifting the robot by the black
plastic picker body can damage the robot.
Chapter 12 Installing, Removing, and Replacing
Replacing the Control Module
1
Y-rail in unlocked, functional
position
389