Scalar I500 User's Guide - Quantum scalar i500 User Manual

Hide thumbs Also See for scalar i500:
Table of Contents

Advertisement

Scalar i500 User's Guide

For FC tape drives:
(Data Path Failover) — You can enable data path failover on HP
DPF
LTO-5 Fibre Channel tape drives with a Storage Networking license
by selecting the DPF check box (see
on page 156).
• The loop ID can be set to a value from 0 to 125. A unique loop ID is
selected by default for all FC tape drives installed in the library. For
example, the tape drive installed in the top drive bay of a control
module is assigned a default loop ID of 61. The tape drive installed in
the control module's bottom drive bay is assigned a default loop ID
of 63.
If you change the default loop IDs, make sure each FC tape drive with
a topology setting of Auto (LN), Loop (L), or Auto (NL) has a unique
loop ID.
You cannot change the Loop ID if the Topology is set to Point to
Point.
• The requested topology connection mode can be set to one of the
following:
— Auto-configure trying L-Port first
Auto (LN)
— Force L-Port
Loop (L)
Point to Point
Chapter 3 Configuring Your Library
Configuring Data Path Failover
— Force N-Port
Setting Tape Drive Parameters
84

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents