Quantum scalar i500 User Manual page 562

Hide thumbs Also See for scalar i500:
Table of Contents

Advertisement

No.
Flag
31
Hardware B
32
Primary
interface
33
Eject media
34
Microcode
update fail
35
Drive humidity
36
Drive
temperature
37
Drive voltage
38
Predictive
failure
Scalar i500 User's Guide
Recommended Application Client
Severity
Message
C
The tape drive has a hardware fault:
1. Turn the tape drive off and then on
again.
2. Restart the operation.
3. If the problem persists, call the tape
drive supplier help line.
W
The tape drive has a problem with the
host interface:
1. Check the cables and cable
connections.
2. Restart the operation.
C
The operation has failed:
1. Eject the tape or magazine.
2. Insert the tape or magazine again.
3. Restart the operation.
W
The microcode update has failed
because you have tried to use the
incorrect microcode for this tape drive.
Obtain the correct microcode and try
again.
W
Environmental conditions inside the
tape drive are outside the specified
humidity range.
W
Environmental conditions inside the
tape drive are outside the specified
temperature range.
W
The voltage supply to the tape drive is
outside the specified range.
C
A hardware failure of the tape drive is
predicted. Call the tape drive supplier
help line.
Probable Cause
The drive has a
hardware fault that is
not read/write
related or requires a
power cycle to
recover.
The drive has
identified an
interface fault.
Error recovery
action.
Microcode update
failed.
Drive humidity
limits exceeded.
Cooling problem.
Drive voltage limits
exceeded.
Predictive failure of
drive hardware.
543

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents