Quantum scalar i500 User Manual page 558

Hide thumbs Also See for scalar i500:
Table of Contents

Advertisement

No.
Flag
7
Media life
8
Not data grade
9
Write protect
10
Media removal
prevented
11
Cleaning media
12
Unsupported
format
13
Recoverable
mechanical
cartridge failure
Scalar i500 User's Guide
Recommended Application Client
Severity
Message
W
The tape cartridge has reached the end
of its calculated useful life:
1. Copy any data you need to another
tape.
2. Discard the old tape.
W
The tape cartridge is not data-grade.
Any data you write to the tape is at risk.
Replace the cartridge with a data-grade
tape.
C
You are trying to write to a write-
protected cartridge. Remove the write-
protection or use another tape.
I
You cannot eject the cartridge because
the tape drive is in use. Wait until the
operation is complete before ejecting the
cartridge.
I
The tape in the drive is a cleaning
cartridge.
I
You have tried to load a cartridge of a
type which is not supported by this
drive.
C
The operation has failed because the
tape in the drive has experienced a
mechanical failure:
1. Discard the old tape.
2. Restart the operation with a different
tape.
Probable Cause
The media has
exceeded its specified
life.
The drive has not
been able to read the
MRS* stripes.
Write command is
attempted to a write-
protected tape.
Manual or software
unload attempted
when prevent media
removal on.
Cleaning tape loaded
into drive.
Attempted load of
unsupported tape
format.
Tape snapped/cut or
other cartridge
mechanical failure in
the drive where
medium can be
demounted.
539