Scalar i500 User's Guide
Removing and Replacing the Library Control Blade and LCB Compact Flash Card
Once the Firmware has been transferred from the computer to the
library the login screen appears.
Caution:
The appearance of the login screen on the Web
browser does NOT mean the firmware upgrade has
completed on the library; it is just an indication that
the firmware image has been moved to the
LCB/compact flash card. A 14U library with six tape
drives installed can take up to 50 minutes to complete
this process. Actual time may vary. You will not be
able to log in until the firmware upgrade is complete.
Caution:
Do NOT remove power from the library while the
firmware is upgrading.
The library operator panel may display the following "upgrade in
progress" message; or it may blank out or change multiple times
during the firmware upgrade process.
23 When the firmware upgrade is complete, the login screen appears on
the operator panel.
Chapter 12 Installing, Removing, and Replacing
417