Scalar i500 User's Guide

9 Install the module terminators.
Caution:
The module terminator is not the same as a SCSI
terminator. Using a SCSI terminator instead of a
module terminator will damage the library.
a Using the module terminators, terminate the top and bottom
modules in the library stack. Install one module terminator in the
top terminator connector on the topmost module and one in the
bottom terminator connector on the bottommost module.
If your library configuration consists of a single module, place
module terminators in the module's top and bottom module
terminator connectors.
b
If you need to add expansion modules to the control module,
remove the module terminator from the control module
terminator connection that is closest to the expansion module.
Replace the module terminator in the expansion module
c
terminator connection furthest from the control module.
10 Connect the module-to-module cable from the control module to the
expansion module.
11 Connect an Ethernet cable to the Gigabit (GB) Ethernet port on the
Library Control Blade (LCB) for remote access to the library via the
Web client.
12 Connect a power cord to the outlet on the power supply on the rear of
the library.
There should always be a power cord connected to the power supply
on the control module. If redundant power supplies are used,
connect a power cord to each of the additional power supply outlets.
13 Power on the library.
a Turn on the rear power switch of each of the power supplies.
b
Turn on the front power button.
c
Power up the host system.
14 Verify communication with all devices on the bus.
15 Configure the library using the commands on the operator panel. See
configuration information in
Chapter 12 Installing, Removing, and Replacing
Configuring Your Library
Cabling the Library
on page 52.