Y Errors - Lexmark CX825 Service Manual

Hide thumbs Also See for CX825:
Table of Contents

Advertisement

Action
Step 11
Replace the controller board. See
page
677.
Does the problem remain?

12y errors

120 error messages
Error code Description
120.80
Motor (fuser) did not turn on.
120.81
Motor (fuser) did not turn off.
120.82
The motor (fuser) speed did not ramp up to the
required level.
120.83
The motor (fuser) stalled.
120.84
The motor (fuser) ran too slow.
120.85
The motor (fuser) ran too fast.
121 error messages
Error code Description
121.00
Fuser did not reach the required temperature
(during warmup).
121.02
Fuser went over the required temperature (during
EWC/Line voltage detection).
121.03
Fuser hardware and driver are mismatched.
121.09
Fuser did not reach the required temperature for
motors (not applicable to standby mode).
121.10
Fuser did not reach the required temperature
(during start of EWC/Line voltage detection).
121.11
Fuser reached the required temperature (during
final EWC/Line voltage detection) too late.
121.12
Fuser did not reach the required temperature
(during final EWC/Line voltage detection).
121.13
Fuser reached the required temperature (during
final EWC/Line voltage detection) too fast.
121.15
Power of fuser heater is too high.
"Controller board removal" on
Diagnostic information
410
Yes
Contact the next
level of support.
Action
See
"Motor (fuser) failure service check" on
page
412.
Action
See
"Fuser failure service check" on page
413.
7564
No
The problem is
solved.