Staging inner transport 1 jam service check
Action
Step 1
a
Check the MSHPF for proper installation, and then check its
paper path. See
"Procedure before starting the MSHPF
service checks" on page
b
Enter the Diagnostics menu, select Output bin quick feed >
select bin, and then touch Continuous.
Does the problem remain?
Step 2
Check door J5 for misalignment and damage.
•
Check the door for wear, damage, and contamination.
•
Check the door for missing rollers.
•
Check the door hinges for proper installation.
•
Check if the door can properly close.
Is the door properly installed and free of damage?
Step 3
Reinstall or replace the door.
Does the problem remain?
Step 4
a
Enter the Diagnostics menu, and then navigate to:
Output device diagnostics > Sensor tests > Finisher
b
Find the sensor (Inner transport 1).
Does the sensor status change while toggling the sensor?
Step 5
Reseat the sensor cable, and then check the sensor for
misalignment and damage.
Is the sensor properly installed and free of damage?
Step 6
Reinstall or replace the sensor. See
transport 1) removal" on page
Does the problem remain?
256.
"Sensor (staging inner
1182.
Diagnostic information
321
Yes
No
Go to step 2.
The problem is
solved.
Go to step 4.
Go to step 3.
Go to step 4.
The problem is
solved.
Go to step 7.
Go to step 5.
Go to step 7.
Go to step 6.
Go to step 7.
The problem is
solved.
7564