Action
Step 2
Check door J6 for misalignment and damage.
•
Check the door for wear, damage, and contamination.
•
Check the door for missing rollers.
•
Check the door hinges for proper installation.
•
Check if the door can properly close.
Is the door properly installed and free of damage?
Step 3
Replace or reinstall the door.
Does the problem remain?
Step 4
a
Enter the Diagnostics menu, and then navigate to:
Output device diagnostics > Sensor tests > Finisher
b
Find the sensor (Inner transport 2).
Does the sensor status change while toggling the sensor?
Step 5
Reseat the sensor cable, and then check the sensor and its
actuator for misalignment and damage.
Is the sensor properly installed and free of damage?
Step 6
Reinstall or replace the sensor. See
transport 2) removal" on page
Does the problem remain?
Step 7
a
Enter the Diagnostics menu, and then navigate to:
Output device diagnostics > Motor tests > Finisher > Staging,
outer and inner transport
b
Touch Start.
Does the motor run?
Step 8
Reseat the motor cable, and then check the motor for misalignment
and damage.
Is the motor properly installed and free of damage?
"Sensor (staging inner
1183.
Diagnostic information
326
Yes
No
Go to step 4.
Go to step 3.
Go to step 4.
The problem is
solved.
Go to step 7.
Go to step 5.
Go to step 7.
Go to step 6.
Go to step 7.
The problem is
solved.
Go to step 10.
Go to step 8.
Go to step 10.
Go to step 9.
7564