8
Release the E-clip (G).
9
Remove the adjuster assembly (H), and then carefully remove the printhead (J).
Note: To minimize printhead misalignment, do not change the length of the adjuster assembly during
removal.
Installation warning: The edges of the frame may be sharp. Do not let the edges of the frame scrape the
printhead or cables. Scraped strips or shavings may contaminate the printhead and cause print quality
issues.
H
J
Repair information
638
G
7564