Dtc B1511: Temperature Control Actuator (Position Sensor) And/Or Its Circuit Malfunction - Suzuki 2006 SX4 Service Manual

Hide thumbs Also See for 2006 SX4:
Table of Contents

Advertisement

7B-61 Air Conditioning System: Automatic Type
DTC Troubleshooting
Step
1
Was "Air Conditioning System Check" performed?
2
Wire harness check
1) Turn ignition switch to OFF position.
2) Disconnect connectors from sunload sensor and HVAC
control module.
3) Check for proper connection to each signal circuit
terminal and ground circuit terminal of sunload sensor
and HVAC control module connectors.
4) If OK, check that sunload sensor circuit is as follows.
• Wiring harness resistance of each sunload sensor
signal circuit and ground circuit is less than 3 Ω
• Insulation resistance of each sunload sensor signal
circuit and ground circuit between sunload sensor
connector and vehicle body ground is Infinity
• Circuit voltage of each sunload sensor signal circuit
and ground circuit is 0 – 1 V with ignition switch turned
ON
Are they in good condition?
3
Sunload sensor power supply voltage check
1) Connect connector to HVAC control module with ignition
switch turned OFF.
2) Turn ignition switch to ON position.
3) Measure voltage between signal terminal and ground
terminal of sunload sensor connector.
Is voltage 4.5 – 5.5 V?
4
Sunload sensor check
1) Check sunload sensor for performance referring to
"Sunload Sensor Inspection".
Is it in good condition?

DTC B1511: Temperature Control Actuator (Position Sensor) and/or Its Circuit Malfunction

Wiring Diagram
2
GRY/BLU
GRY/RED
3
[P]
[S]
[G]
4
[P]: Position sensor power supply circuit
[S]: Position sensor signal circuit
Action
1
12V
G20-1
G20-2
5V
5V
WHT
G20-12
YEL
G20-27
ORN
G20-24
[G]: Position sensor ground circuit
1. HVAC control module
Go to Step 2.
Go to Step 3.
Go to Step 4.
Substitute a known-
good HVAC control
module and recheck.
14
13
12
11
10
9
8
30
29
28
27
26
25
24
2. Temperature control actuator
3. To air flow control actuator
Yes
Go to "Air Conditioning
System Check".
Sunload sensor power
supply circuit and/or
signal circuit are open,
short or high resistance.
Substitute a known-
good HVAC control
module and recheck.
Replace sunload
sensor.
G20
7
6
5
4
3
23
22
21
20
19
18
17
4. To other sensors
No
S6RW0C7224013
2
1
16
15
I6RW0C722004-01

Advertisement