Suzuki 2006 SX4 Service Manual page 1047

Hide thumbs Also See for 2006 SX4:
Table of Contents

Advertisement

Step
3
Floor harness circuit check for wagon model
1) With ignition switch turned OFF, remove rear inner trim
of right side and disconnect "L395" connector.
2) Check for proper connection to applicable side curtain-
air bag at terminal in "L395" connector.
3) If OK, release shorting bar in SDM connector inserting
release tool (1) included in special tool (A).
Special tool
(A): 09932–76010
4) Measure resistance between "L04-19" terminal and body
ground, and between "L04-20" terminal and body ground
(for DTC B1363).
5) Measure resistance between "L04-21" terminal and body
ground, and between "L04-22" terminal and body ground
(for DTC B1367).
"L395"
Is each measured resistance infinity?
NOTE
Upon completion of inspection and repair work, perform the following items.
• Reconnect all air bag system components, ensure all components are properly mounted.
• Clear DTCs referring to "DTC Clearance", if any.
• Repeat "Air Bag Diagnostic System Check" to confirm that the trouble has been corrected.
Action
"L04-19"
"L04-20" "L04-21"
"L04-22"
(A)
I7RW01822093-01
Yes
DTC B1363: Repair
"YEL/GRN" or "YEL/
BLU" circuit for short to
ground at driver curtain-
air bag harness.
DTC B1367: Repair
"BLK/YEL" or "BRN/
YEL" circuit for short to
ground at passenger
curtain-air bag harness.
1
Air Bag System:
8B-82
No
DTC B1363: Repair
"YEL/GRN" or "YEL/
BLU" circuit for short to
ground at floor harness.
DTC B1367: Repair
"BLK/YEL" or "BRN/
YEL" circuit for short to
ground at floor harness.

Advertisement

Table of Contents
loading