E1 ISDN PRI Installation

This section describes the configuration procedures necessary to implement E1 ISDN PRI
signaling for European, Pacific Rim, and other emerging markets. Please carefully follow
the procedures step by step.
1. Change the Configure Type to E1:
a.
From Boards view, double-click the board to be configured to open the Board
Configuration window.
b.
In the Board Configuration window, click the Board Configuration button.
c.
In the next Board Configuration window, select E1 as the configure type, and
click OK.
Important:
When changing from E1 to T1, then back to E1, channel group properties will
be reset to default values. It is important to make sure the channel group
properties are configured properly. Follow the steps below to re-check your
settings for the physical layer and data link layer.
2. In the Board Configuration window, double-click the channel group.
Figure 189. Physical Layer
Consult your CO for "Frame Type," "Line Code," or "Zero Code Suppression."
Do not check the System Clock Master check box because the CO is a clock pro-
vider, and our system is synchronized to the CO. If all configurations are correct,
432
MAXCS ACM 6.7 Administration Manual