Configuring the Triton T1/E1 Board
AT&T 5ESS PRI
•
•
NT DMS-100 PRI
•
NI-2 PRI (default)
The bottom four settings are used for a PRI tie trunk configuration where two MAXCS
systems are connected back to back. In such a configuration, one MAXCS system must
be configured as Network and the other as User. For example, set one to NI-2 PRI
Network and the other to NI-2 PRI.
•
AT&T 4ESS PRI Network
•
AT&T 5ESS PRI Network
•
NT DMS-100 PRI Network
NI-2 PRI Network
•
If you select a Span Type of Regular ISDN PRI in the E1 PRI Configuration Window, use
the following guidelines to set the ISDN PRI Switch mode.
E1 PRI
Figure 82. E1 PRI Switch Mode
The top three settings are used for a connection to a CO switch:
•
Austel TS014 PRI
ETSI NET5PRI
•
•
NT DMS-100 PRI
The bottom three settings are used for a PRI tie trunk configuration where two MAXCS
systems are connected back to back. In such a configuration, one MAXCS system must
be configured as Network and the other as User. For example, set one to NT DMS-100
PRI Network and the other to NT DMS-100 PRI.
Austel TS014 PRI Network
•
•
ETSI NET5PRI Network
•
NT DMS-100 PRI Network
152
MAXCS ACM 6.7 Administration Manual