Upgrading Release 9/10r to Avaya DEFINITY Server R
running Avaya MultiVantage Software
Disable Scheduled Maintenance and Alarm
Origination
To prevent scheduled daily maintenance from interfering with the upgrade:
1. To prevent scheduled daily maintenance from interfering with the update or
upgrade, type change system-parameters maintenance and press
RETURN
2. If scheduled maintenance is in progress, set the Stop Time field to 1
minute after the current time.
or
If scheduled maintenance is not in progress, set the Start Time field to a
time after the upgrade will be completed.
For example, if you start the upgrade at 8:00 P.M. and the upgrade takes
90 minutes, set the Start Time field to 21:30.
!
3. Type neither in the Alarm Origination to OSS Numbers field and
press

Busyout MMI Circuit Packs

High and Critical Reliability only if necessary
!
CAUTION:
Multimedia-to-voice station calls are not preserved on an upgrade. Failure to
busy-out the TN787 Multimedia Interface (MMI) circuit packs results in
unusable TN787 and TN787 Multimedia Voice Conditioner ports.
1. Type display system-parameters customer-options and press
On screen 2 under the Multimedia Call Handling (MMCH) options, check
the Basic and Enhanced fields.
2. If either the Basic or Enhanced field is y, type list configuration all and
press
3. If there are MMI circuit packs, type busyout board UUCSS for each MMI
circuit pack.
1-20
Issue 5 October 2002
.
CAUTION:
If you do not disable Alarm Origination, the system can generate
alarms, resulting in unnecessary trouble tickets.
ENTER.
to locate all MMI (TN787) circuit packs.
RETURN
.
RETURN
555-233-115