C
6: DCC C
HAPTER
ONFIGURATION
n
Configuring Advanced
DCC Functions
Configuring ISDN caller identification callback with RS-DCC
Configuring ISDN caller identification callback with RS-DCC involves configuring
the server end and the client end.
1 Configure the client of ISDN caller identification callback
Follow these steps to configure the client of ISDN caller identification callback:
To do...
Enter system view
Enter dialer interface view
Configure a dial string for
calling a remote end
Set the interval between two
calls
2 Configure the server of ISDN caller identification callback
Follow these steps to configure the server of ISDN caller identification callback:
To do...
Enter system view
Enter dialer interface view
Configure the local end to place
ISDN return calls for the specified
ISDN calling number
Configure a dial string for calling a
remote end
The number configured in the dialer number command on the dialer
interface is not required to be same as the incoming number.
To leave enough time for a server to call back, the interval between two calls
on the client need to be at least 10 seconds longer than that of the server. It is
recommended that the interval on the server be set to 5 seconds (the default)
and that on the client be set to 15 seconds.
Configuring advanced DCC functions involves:
"Configuring ISDN leased line" on page 176
"Configuring auto-dial" on page 177
"Configuring circular dial string backup" on page 177
Configuring ISDN leased line
ISDN leased line can be configured with C-DCC but not RS-DCC. This function is
fulfilled through establishing semi-permanent ISDN MP connections. Such
application requires that a leased line has been established on the PBX of your
telecom service provider and has been connected to the remote device.
Use the command...
system-view
interface dialer
interface-number
dialer number dial-number
dialer timer enable seconds Optional
Use the command...
system-view
interface dialer interface-number
dialer call-in remote-number callback Required
dialer number dial-number
Remarks
--
--
Required
15 seconds is recommended.
Remarks
--
--