Displaying And Maintaining Ce3 Interfaces - 3Com MSR 50 Series Configuration Manual

3com msr 30-16: software guide
Hide thumbs Also See for MSR 50 Series:
Table of Contents

Advertisement

To do...
Enter CE3 interface view
Configure to perform BERT
test on the CE3 interface
Configure to perform BERT
test on an E1 channel created
on the CE3 interface
Set the clock
mode
Set the national bit
Set CRC check for serial
interfaces formed on the CE3
interface
Enable
loopback
Set E1 framing format on an
E1 line
Quit to system view
Enter synchronous serial
interface view of an interface
formed by a CE3 interface
Set the CRC mode
Displaying and
Maintaining CE3
Interfaces
c
CAUTION: An interface is disabled when being shut down. So, perform
operations of this type with caution.
You can verify the configuration of a CE3 interface by using the display
commands listed in the following table in any view.
Use the command...
controller e3
interface-number
bert pattern { 2^7 | 2^11 |
2^15 | qrss } time number
[ unframed ]
e1 line-number bert pattern
{ 2^11 | 2^15 | 2^20 | 2^23 |
qrss } time number
[ unframed ]
For the CE3
clock { master | slave }
interface
For an E1 line
e1 line-number set clock
{ master | slave }
national-bit { 0 | 1 }
crc { 16 | 32 | none}
For the CE3
loopback { local | payload |
interface
remote }
For an E1 line
e1 line-number set loopback
{ local | payload | remote }
e1 line-number set
frame-format { crc4 |
no-crc4 }
quit
interface serial
number/line-number:0
or
interface serial
number/line-number:set-num
ber
crc { 16 | 32 | none }
CE3 Interface
121
Remarks
Required
Optional
Optional
Optional
The default is slave, that is,
line clock.
Optional
The default is slave, that is,
line clock.
Optional
The default is 1.
Optional
The default is 16-bit CRC.
Optional
Loopback is disabled by
default.
Optional
The default is no-CRC.
-
Required
Optional
By default, 16-bit CRC is
adopted.

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents