The initiator of asynchronous RTC terminal access is an RTC client connected to
the monitoring device. The receiver of asynchronous RTC terminal access is the
RTC server connected to the monitored device. An RTC client can initiate a
connection request to the RTC server at any time to access the data.
Follow these steps to perform basic RTC initiator (RTC client) configuration:
To do...
Enter system view
Enable terminal access on
the router
Create a terminal template
and enter terminal
template view
Create a RTC client VTY
Return to system view
Enter interface view
Configure the
asynchronous serial
interface to operate in the
flow mode
Apply the template to the
interface
Return to system view
Enter TTY user interface
view
Enable software flow
control of data on the
current user interface
For details about the async mode flow command, refer to the async mode
command in
"WAN Interface Configuration" on page
After a template is applied on an interface, you need to set the flow control
mode of the user interface corresponding to the interface to software flow
control. You can use the display user-interface command to display the
associations between interfaces and user interfaces.
For details about the user-interface command, refer to the user-interface
command in
"User Interface Configuration" on page
For details about the flow-control software command, refer to the
flow-control command in
Follow these steps to perform advanced RTC initiator (RTC Client) configuration
Use the command...
system-view
rta server enable
rta template template-name
vty vty-number rtc-client
remote ip-address
port-number [ source
source-ip ]
quit
interface interface-type
interface-number
async mode flow
rta terminal template-name
terminal-number
quit
user-interface { first-num1
[ last-num1 ] | tty first-num2
[ last-num2 ] }
flow-control software
"User Interface Configuration" on page
Remarks
-
Required
Disabled by default
Required
Required
After this configuration, the
template cannot be configured
with any TTY, Telnet, or RTC
server VTYs.
-
Required
The interface type must be
supported by terminal access.
Required
By default, an asynchronous
serial interface operates in the
protocol mode and an AUX
interface the flow mode.
Required
-
-
Required
By default, the flow control
mode is none; that is, no flow
control is implemented.
99.